Loosen clamp (1).
Disconnect fitting (2).
Remove the air filter assembly (3) and duct cover (4).
Empty the cooling circuit.
Turn away bolts (5), nozzle screw (6) and remove the bracket (7).
Disconnect the coolant temperature sensor electrical connector (8).
Attention. Do not use tools during removal and installation that will damage the sensor and its mating plane. Replace the sensor if it has been dropped or hit hard.
Do not use the temperature sensor during operation as a stop or support.
Remove the fluid temperature sensor (8).
Disconnect the clamp (9) hose of the cooling system and move aside the tube (10) and hoses (11).
Turn away bolts (12) coolant outlet block.
Slide the electrical harness (13).
Remove the coolant outlet block.